2026-08-22
Падение напряжения адресных LED 24В
Падение напряжения адресных LED 24В
Расчет кабеля и точек подачи питания для LED-фасада.
Электрическая модель
I=P/V; R=2ρL/A; ΔV=IR; cable loss=I²R. The calculation must include positive and return conductors [S2].
Расчетный пример
Example assumption: 10m × 19.2W/m at 24V = 192W and 8A. A 15m one-way 2.5mm² copper feeder gives 1.68V calculated drop. Two shorter 4A branches reduce the calculated drop to 0.56V each. Verify with approved products and full-load measurements.
Ограничения и безопасность
- No universal allowable percentage applies.
- Do not parallel different supplies without an approved design.
- Fuse and label every injection branch.
- Technical reviewer: 待确认.
Sources
Author: LikeLight Tom, Operations. Evidence reviewed August 21, 2026.
Project inquiry