2026-08-24

Korrosion von LED-Fassaden an der Küste

Korrosion von LED-Fassaden an der Küste

Korrosion von LED-Fassaden an der Küste

Mischmetalle, Steckverbinder und Salzsprühgrenzen.

Mechanismus

Galvanic corrosion requires dissimilar metals, electrical contact and an electrolyte [S2]. Review housing, bracket, fastener, connector and substrate as one material stack.

Quantifiziertes Beispiel

Illustrative screen: 100 interfaces with 300mm² cathodic area and 10mm² coating damage each produce a 30:1 exposed-area ratio. This identifies inspection priority; it is not a corrosion-rate prediction.

Freigabekriterien

  • Salt-mist hours are comparative, not a universal service-life conversion [S1].
  • Repair field-drilled coating damage.
  • Resolve corrosion isolation versus protective bonding.
  • Technical reviewer: 待确认.

Sources

  1. IEC salt-mist method
  2. NASA corrosion forms
  3. NASA bonding guide
  4. LIKELIGHT wall-washer family

Author: LikeLight Tom, Operations. Evidence reviewed August 22, 2026.