2026-10-23

AC60V 40mm Amusement Point Lights: Match the Branch, Base and Load

A replacement lamp may screw into a holder and still be the wrong order: the branch may be overloaded, the base dimensions may differ, or the installation may need protection the product page does not specify. Start with voltage, quantity and the actual mounting interface.

30-second answer

  • Consider it for a steady point effect: The LIKELIGHT listing identifies a 40mm, AC60V, 2W, single-colour point light with 360-degree emission.
  • Check the existing branch: Count the lamps and calculate connected watts before replacing a full row; keep the supply type and voltage consistent.
  • Do not release a batch until: The holder/base drawing, branch protection and complete installed environmental protection are confirmed. The listing does not publish an IP rating.

What visual result does a point lamp create?

A 360-degree point source is visible from more directions than a forward-facing strip, so it can suit outlines or ride structures where separate lamps are seen around each mounting point. It creates spaced points, not a continuous line.

Choose this form when the design expects visible lamp spacing. If the goal is an unbroken luminous contour, compare a continuous linear product instead; changing the point lamp will not remove dark gaps between mounting locations.

What is confirmed about this AC60V model?

The product listing names model L-D-E14-2835/3528-60V and identifies a 40mm, AC60V, 2W single-colour light with 360-degree emission. It lists SMD2835/3528 LED options.

The page does not establish a universal holder standard or a control protocol. Treat the model suffix as an identifier, not a dimensional drawing: match thread, shoulder, contact and clearance against the existing holder before ordering.

Estimate the branch load before replacing a row

For a steady AC branch, the connected real power is a useful first estimate: lamp count × rated watts per lamp. The result helps compare a proposed replacement row with the branch’s existing load schedule.

This arithmetic is not a circuit approval. Supply protection, inrush, wiring condition, power factor and local electrical rules still govern the final design. A qualified person should verify the installed branch before energizing a replacement batch.

Do not infer pixel addressing from the product name

The page calls the product a “pixel point light,” but it identifies single-colour output and does not specify an addressable IC, data input or protocol. The word pixel alone is not proof that each lamp can be animated separately.

If the ride effect must chase from point to point, stop and obtain the exact control wiring and protocol for the selected model. If steady single-colour illumination is enough, the purchasing decision can focus on electrical and mechanical fit instead.

Base fit and environmental protection are separate checks

The product page does not publish an IP rating. A 360-degree light can be visually suitable while the assembled holder, connector and wiring still need a separate environmental review.

Confirm the holder dimensions and sealing arrangement from a drawing or sample. For exposed rain, wash-down or condensation, do not assume suitability from the amusement application label; verify the complete installed assembly and maintenance access.

Worked example: 100 replacement points

The example adds 200W of lamp load and gives a first-order 3.33A estimate. It does not size a transformer or approve a ride circuit. Use the result to ask the electrician to verify the existing branch and to request a representative sample before replacing the full row.

Assume 100 lamps, each at the listed 2W, supplied from the specified AC60V branch. Formula: lamp count × watts per lamp; current estimate = total watts ÷ voltage.

Hypothetical replacement row; use 2W only where the ordered configuration matches the published listing.

  1. Connected power

    Calculation
    100 × 2W = 200W

    Meaning
    Estimated steady lamp load

  2. Current estimate

    Calculation
    200W ÷ 60V ≈ 3.33A

    Meaning
    Before power factor, inrush and design margin

  3. Purchase decision

    Calculation
    Compare 3.33A with the verified branch schedule

    Meaning
    Do not approve replacement until wiring and protection are checked

Conditional replacement table

Check each site condition before choosing
Site condition Buyer decision
Each point must run an independent chase. Do not assume this single-colour listing is addressable; obtain a confirmed data model or choose a documented pixel product.
A visible spaced point effect is intended. A 360-degree point lamp may suit the visual form if pitch and viewing distance work.
The holder is in a dry protected cabinet. Confirm base fit and electrical connection with a drawing or sample.
The lamp or holder is exposed to rain or wash-down. No IP rating is published; verify the entire assembled protection or do not shortlist it.
Many lamps share one AC60V branch. Multiply count by rated watts, then have branch wiring and protection checked.
The project requires DMX, SPI or network control. The listing names no protocol; select only after written control compatibility is confirmed.

A conditional case: LIKELIGHT L-D-E14-2835/3528-60V

This model can be considered for a replacement row when the existing branch is AC60V, the desired effect is steady single-colour points, and a drawing or physical sample confirms the holder and clearance.

The page lists 2W, 40mm and 360-degree emission, but no IP rating. It also does not define pixel addressing. For an exposed ride, the quotation should resolve the completed holder/connector protection and the electrical acceptance check before the buyer commits to a batch.

Published model facts
Item Published value
Model L-D-E14-2835/3528-60V
Diameter 40mm
Rated power 2W per light
Working voltage AC60V
Light form Single colour; 360-degree emission
Environmental rating No IP rating published on the page
LIKELIGHT 40mm point light shown from the LED face and threaded base.
LIKELIGHT 40mm point light shown from the LED face and threaded base.
Four 40mm point lights showing the circular LED board and threaded mounting bases.
Four 40mm point lights showing the circular LED board and threaded mounting bases.

Make the replacement RFQ comparable

  1. 1. Existing circuitState AC/DC type, nominal voltage, existing lamp count and branch protection.
  2. 2. Mounting fitSend holder/thread dimensions, panel thickness and rear clearance, or request a drawing/sample.
  3. 3. Light appearanceChoose the required colour and point spacing; attach a photo of the installed row.
  4. 4. Site exposureDescribe rain, wash-down, condensation and access for replacement; ask for the assembled protection boundary.
  5. 5. Complete offerAsk the quote to state exact model/options, dimension and wiring drawings, BOM, sample and acceptance points, system price, spares and lead time.

These details let the buyer compare replacement fit and total installed scope, not just the price of one lamp.

Buyer questions

Does the E14 in the model name guarantee a standard E14 fit?

No. Use the model name as an identifier and confirm thread and contact dimensions against an approved drawing or sample.

Can I connect 100 lamps to one branch?

The example gives a 200W, about 3.33A first estimate at 60V. Branch capacity depends on the installed wiring and protection; have it checked before energizing.

Is it suitable outdoors?

The page does not publish an IP rating. Confirm protection of the complete lamp, holder, connector and wiring assembly for the actual exposure.

Can it create chasing pixel effects?

No control IC or protocol is specified on the listing. Obtain written control details or select a documented addressable model for that requirement.

Copy-ready replacement inquiry

We are replacing [quantity] point lights on an existing [AC/DC, voltage] branch. Existing holder: [drawing/photo/dimensions]. Required colour and spacing: [ ]. Site exposure: [ ]. Please confirm the exact model, mechanical fit, wiring, assembled protection and sample plan. We would like to test one representative sample before the batch quotation.